Uploads by Maddie
Jump to navigation
Jump to search
This special page shows all uploaded files.
Date | Name | Thumbnail | Size | Description | Versions |
---|---|---|---|---|---|
15:31, 5 May 2015 | Transient 0.5e-10 without SRH.png (file) | Error creating thumbnail: /bin/bash: /usr/bin/convert: No such file or directory
Error code: 127 |
28 KB | Process Examples - Simple Diode First part, transient analysis of IV curve at time 0.5e-10 seconds. | 1 |
15:55, 5 May 2015 | Gaussian Implant Profile.png (file) | Error creating thumbnail: /bin/bash: /usr/bin/convert: No such file or directory
Error code: 127 |
25 KB | Process Examples - Simple Diode Implant Profile of silicon diode with a constant p-type doping of 1e16 and an n-type Gaussian w/ peak concentration of 1.0e20 and a junction depth of 0.1um. | 1 |
16:39, 5 May 2015 | Transient with SRH lifetime e-11.png (file) | Error creating thumbnail: /bin/bash: /usr/bin/convert: No such file or directory
Error code: 127 |
50 KB | Process Examples - Simple Diode Transient plot of I-V for diode with SRH generation recombination lifetime of 1e-11 s. | 1 |
16:40, 5 May 2015 | Transient with SRH lifetimes of e-6.png (file) | Error creating thumbnail: /bin/bash: /usr/bin/convert: No such file or directory
Error code: 127 |
51 KB | Process Examples - Simple Diode Transient plot of I-V for diode with SRH generation recombination lifetime of 1e-6 s. | 1 |
17:12, 5 May 2015 | 900 C for 60mins Part 1.png (file) | Error creating thumbnail: /bin/bash: /usr/bin/convert: No such file or directory
Error code: 127 |
44 KB | Model Development Solutions Implant profile for Carbon diffusion in Silicon at 900 degrees Celsius for 60 minutes | 1 |
17:13, 5 May 2015 | 1000 C for 30 mins Part 1.png (file) | Error creating thumbnail: /bin/bash: /usr/bin/convert: No such file or directory
Error code: 127 |
46 KB | Model Development Solutions Implant profile for Carbon diffusion in Silicon at 1000 degrees Celsius for 30 minutes | 1 |
17:14, 5 May 2015 | 1100C for 10 mins Part 1.png (file) | Error creating thumbnail: /bin/bash: /usr/bin/convert: No such file or directory
Error code: 127 |
46 KB | Model Development Solutions Part 1 Implant profile for Carbon diffusion in Silicon at 1100 degrees Celsius for 10 minutes | 1 |
17:15, 5 May 2015 | 1100 C for 10 mins Part 2.png (file) | Error creating thumbnail: /bin/bash: /usr/bin/convert: No such file or directory
Error code: 127 |
48 KB | Model Development Solutions Part 2 Implant profile for Carbon diffusion in Silicon at 1100 degrees Celsius for 10 minutes | 1 |
17:16, 5 May 2015 | 1000C for 30 min Part 2.png (file) | Error creating thumbnail: /bin/bash: /usr/bin/convert: No such file or directory
Error code: 127 |
45 KB | Model Development Solutions Part 2 Implant profile for Carbon diffusion in Silicon at 1000 degrees Celsius for 30 minutes | 1 |
17:17, 5 May 2015 | 900 C for 60min Part 2.png (file) | Error creating thumbnail: /bin/bash: /usr/bin/convert: No such file or directory
Error code: 127 |
45 KB | Model Development Solutions Part 2 Implant profile for Carbon diffusion in Silicon at 900 degrees Celsius for 60 minutes | 1 |
19:32, 13 July 2016 | PRiMESubmissionFigure2.png (file) | Error creating thumbnail: /bin/bash: /usr/bin/convert: No such file or directory
Error code: 127 |
135 KB | Figure 2. a) Drain current versus pH with varied drain bias ranging from 1 V to 5 V with a 1 V increment for a 1um gate length device. b) Corresponding sensitivity versus pH. c) Corresponding percent of available surface charge at the gate contact vs. | 1 |
19:35, 13 July 2016 | PRiMESubmissionFigure3.png (file) | Error creating thumbnail: /bin/bash: /usr/bin/convert: No such file or directory
Error code: 127 |
34 KB | Figure 3. Simulated results of peak sensitivity (mA/mm-pH) as a function of drain voltage, VDS, for a 1um gate length AlGaN/GaN HEMT pH sensor. | 1 |
19:47, 13 July 2016 | PRiMESubmissionFigure4.png (file) | Error creating thumbnail: /bin/bash: /usr/bin/convert: No such file or directory
Error code: 127 |
101 KB | Figure 4. Simulated sensitivity (mA/mm-pH) as a function of pH for varying gate lengths (1.0 m to 10.0 m) at a constant drain bias, VDS, of 2.0 V. | 1 |
19:48, 13 July 2016 | PRiMESubmissionFigure5.png (file) | Error creating thumbnail: /bin/bash: /usr/bin/convert: No such file or directory
Error code: 127 |
58 KB | Figure 5. Simulated sensitivity (mA/mm-pH) as a function of pH for varying gate lengths (0.5 m to 3.0 m) at a constant drain bias, VDS, of 5.0 V. | 1 |
23:17, 15 July 2016 | Hemt ph.pdf (file) | ![]() |
70 KB | Tutorial script for the AlGaN/GaN HEMT chemical sensor. PRiME conference 2016 - Madeline Sciullo, Erin Patrick, Mo Choudhury, Mark Law. | 1 |
23:20, 15 July 2016 | GaN modelfile mo.pdf (file) | ![]() |
60 KB | GaN model file for the heat_ph deck for the PRiME 2016 submission. Madeline Sciullo, Erin Patrick, Mo Choudhury, Mark Law. | 1 |
23:24, 15 July 2016 | Continuity.pdf (file) | ![]() |
32 KB | Header file for hemt_ph script; PRiME 2016 Submission AlGaN/GaN chemical sensors. Madeline Sciullo, Erin Patrick, Mo Choudhury, Mark Law. | 1 |
23:27, 15 July 2016 | Poission.pdf (file) | ![]() |
39 KB | Header file fro hemt_ph script; PRiME 2016 submission AlGaN/GaN HEMT Chemical Sensors. Madeline Sciullo, Erin Patrick, Mo Choudhury, Mark Law. | 1 |
23:31, 15 July 2016 | Poisson.pdf (file) | ![]() |
39 KB | Header file for hemt_ph script; PRiME 2016 Submission for AlGaN/GaN HEMT Chemical Sensor. Madeline Sciullo, Erin Patrick, Mo Choudhury, Mark Law. | 1 |